Tridesclous 2 settings
Tridesclous 2 (SpikeInterface): published defaults
dspk sort tridesclous2 [OPTIONS] --output <OUTPUT> <RECORDING>Arguments
<RECORDING>
Recording (SpikeGLX .bin / .cbin, raw .bin + JSON .meta, NWB, Zarr)
Settings
--source <SOURCE>
Source within the file (an iddspk-cli openlists); default: the largest electrical one--probe <PROBE>: one ofneuropixels1,neuropixels2,tetrode,utah,hdemg4x8,hdemg8x8
Probe preset; default: the geometry the recording carries (SpikeGLX), else an error--probe-file <PROBE_FILE>
Probe file (.json: probeinterface or Kilosort 4) saying which channel each contact is wired to: the data is read in contact order (unconnected contacts left out), with its geometry--progress <PROGRESS>: defaultbar, one ofbar,json
How progress is reported:bar(on stderr) orjson(one JSON object per line on stdout:progressevents, thendoneorerror; for programs running this one)--channel-map <CHANNEL_MAP>
Channel map (.toml / .json, pairs underremap) applied after the probe: channels reordered, dropped, renamed; the geometry follows them--pitch-um <PITCH_UM>: default8000
Electrode pitch of HD-EMG grid presets (µm)--start-sec <START_SEC>: default0
Start of the part to process (s)--duration-sec <DURATION_SEC>
Length of the part to process (s); default: to the end-o, --output <OUTPUT>
Output folder or store--format <FORMAT>
Output format; default: from the name (.nwb.zarr→ nwb, other.zarr→ zarr, else phy)phy: Phy / Kilosort folder (.npyarrays,.tsvtables)zarr: dspk.sorting.zarrstorenwb: NWB/unitstable in a.nwb.zarrstore
--show-config
Print every setting of the run and exit